 Handheld scanning of a statue (enlargement of fringe pattern)

Stereo camera setup with LED based fringe projection
3D overview, picture (with fringe pattern) and 3D detail of a design object
download
|
 |
Measurement principle
 |
Fringe projection with two grating structures rotated by 90° to each other |
 |
Whole body measurement by the use of free moving sensor head |
 |
Highspeed image projection and acquisition |
Features
 |
Virtually unlimited freedom in sensor placement |
 |
Hand-held measurement through 60 Hz fringe projection |
 |
No restrictions in sensor positioning by means of cordless data transmission and battery power supply |
 |
Self calibration of measurement system |
 |
Alternatively software based matching respectively self calibration for whole body measurement |
 |
Optionally capture of color and texture in high resolution |
Applications and offer
 |
3D data for quality control, rapid prototyping, design, CAD/CAM, archaeology and criminology |
 |
Development and manufacturing of equipment according to the specific client need's |
| System Parameters |

Scheme of 3D measurement set-up (self calibration by means of optional linking camera) |
 |
Single measurment fields: |
|
220 mm x 170 mm |
|
550 mm x 425 mm |
 |
Measurement uncertainty: |
|
50 µm ... 150 µm |
 |
Sequence duration: |
|
< 0,25 s |
 |
Number of views: |
|
free |
|
|
|